00:00

QUESTION 1

What is the best approach to handle a hard disk failure on a FortiAnalyzer that supports hardware RAID?

Correct Answer: C
In a hardware RAID setup, FortiAnalyzer supports hot swapping, which allows you to replace a failed disk without shutting down the device. The RAID controller will automatically rebuild the array using the new disk, minimizing downtime and maintaining data integrity.

QUESTION 2

Refer to the exhibit.
FCP_FAZ_AD-7.4 dumps exhibit
The image displays "he configuration of a FortiAnalyzer the administrator wants to join to an existing HA
cluster.
What can you conclude from the configuration displayed?

Correct Answer: A
Operation Mode: The mode is set to "High Availability" which indicates that this FortiAnalyzer is intended
to be part of an HA cluster.
Preferred Role: The "Primary" role is selected, meaning this device is configured to act as the primary
unit in the HA cluster. This is a crucial setting as it determines the device's behavior and responsibilities
within the cluster.
Cluster Virtual IP: A specific IP address (192.168.101.222) is assigned to be used by devices in the
network to communicate with the cluster. This Virtual IP will be shared between the units in the cluster.
Cluster Settings: These include configurations for heartbeat interval, failover threshold, and priority which
are crucial for maintaining cluster health and managing failover scenarios.
Given these points, the correct conclusion from the options provided is:
* C. This FortiAnalyzer will join the existing HA cluster as the primary.

QUESTION 3

View the exhibit:
FCP_FAZ_AD-7.4 dumps exhibit
What does the 1000MB maximum for disk utilization refer to?

Correct Answer: B
The 1000MB maximum for disk utilization refers to the total disk quota allocated for storing logs from all devices within the specific ADOM (Autonomous Domain) you're configuring.

QUESTION 4

Which three RAID configurations provide fault tolerance on FortiAnalyzer? (Choose three.)

Correct Answer: BCD
RAID 1 provides fault tolerance through disk mirroring.
RAID 5 provides fault tolerance by using distributed parity across multiple disks. RAID 6+0 combines striping with double parity, offering enhanced fault tolerance.
RAID 0 and RAID 0+0 do not provide any fault tolerance, as they focus on performance through data striping but offer no redundancy.

QUESTION 5

You finished registering a FortiGate device. After traffic starts to flow through FortiGate, you notice that only some of the logs expected are being received on FortiAnalyzer.
What could be the reason for the logs not arriving on FortiAnalyzer?

Correct Answer: C
When only some of the expected logs from a FortiGate device are being received on FortiAnalyzer, it often indicates a configuration issue on the FortiGate side. Proper logging configuration on FortiGate involves specifying what types of logs to generate (e.g., traffic, event, security logs) and ensuring that these logs are directed to the FortiAnalyzer unit for storage and analysis. If the logging settings on FortiGate are not correctly configured, it could result in incomplete log data being sent to FortiAnalyzer. This might include missing logs for certain types of traffic or events that are not enabled for logging on the FortiGate device.
Ensuring comprehensive logging is enabled and correctly directed to FortiAnalyzer is crucial for full visibility into network activities and for the effective analysis and reporting of security incidents and network performance.